info@dis-floors.com

+45 40 26 1777

monolithic industrial floor disgen

The reinforced monolithic industrial floor.

disgen

The monolithic industrial floor on soft substrates with static, structural or fibre reinforcement.

Area of application

  • Floor slabs on the ground in all kinds of  production or industrial  facilities,
  • Floor panels in deep-freeze and cold stores

Standard version

  • As required 15 – 25 cm thick disgen base slab,
  • Special formulation reinforced with steel, glass, PP fibres or reinforcing steel

Load capacity

Standard

  • area loads up to 100 kN/sqm
  • single loads up to 30 kN/sqm

Surface

  • Surface ready, with wear layers as required,

Flatness

  • According to DIN 18 202, table 3, line 3

Joint

  • Depending on the design and application, 
  • Edge joints between base slab and rising components

Installation conditions

  • Subgrade according to ZTVE-StB 94,
  • Ev2 > 100 MN/sqm, Ev2/Ev< 2,5
  • Insulation layers > 100 kPa for cooling and deep-freeze use
  • Soil frost-free,
  • Roof and exterior walls sealed and closed,
  • draught-free,
  • + 5 °C Minimum temperature